Home / Fault Passage Indicators / Data Concentrator
MPE309

MPE309 Data Concentrator Unit

A pole-mounted communications gateway that collects information from nearby fault indicators and forwards it to a monitoring platform or agreed control-centre interface.

MPE309 equipment available through Mech Power Engineering
FPI equipment supplied through Mech Power Engineering. Final model and configuration are confirmed with your proposal.

From field indication to remote information

The DCU links the local FPI radio network with the backhaul connection. The brochure describes collection of short-circuit and earth-fault events, fault current, load current, battery alarms and device status. A useful installation links each device ID to its feeder, phase and physical location so an alarm can be interpreted by the operating team.

Capacity and radio planning

The stated connection capacity is nine indicators, described as three lines with three phases each. Radio coverage is a site-design issue, not simply a device-count calculation. Distance, structures, vegetation, mounting position and antenna orientation should be checked by a field communication test. The FPI table gives a communication-distance entry of 100 without a unit, so that entry is not treated here as a guaranteed range.

Solar-powered pole assembly

The illustrated assembly combines the enclosure, external antennas, solar module, support bracket and pole straps. Catalogue values include a 30 W solar panel and a 6.4 V, 16.5 Ah battery. Solar exposure, seasonal charging conditions, shading, cable entries and maintenance access must be reviewed for the installation location. Battery autonomy is not specified by the supplied document.

Cellular and SCADA integration

The brochure lists GSM/GPRS/3G/4G variants, dual-SIM standby and configurable IEC 60870-5-101, IEC 60870-5-104 and DNP3 support. The cellular bands, modem variant and protocol implementation must be confirmed before purchase. Integration requires an agreed point list, addressing, timestamps, event handling, reporting intervals and a successful end-to-end test; listing a protocol does not establish interoperability with every SCADA system.

Remote operations and notifications

Listed functions include parameter management, reset commands, low-battery reporting, load-current uploads and maintenance using a handheld tool or SMS commands. Remote control privileges and SMS recipients should be restricted to the agreed operators. The brochure gives differing SMS-recipient limits in different sections, so notification capacity and escalation behaviour must be confirmed with the proposed software and DCU version.

Technical data and selection notes

Values below are transcribed or paraphrased from the supplied manufacturer catalogue. Entries marked for confirmation must be settled in the offered data sheet and approved project documents.

MPE309 — catalogue values
ModelMPE309; narrative also uses MPE309.1 — confirm the ordered revision
Indicator capacityUp to 9 FPIs / three three-phase lines
Solar panel30 W; illustrated module 670 × 350 × 25 mm; maximum voltage 18 V
Battery6.4 V, 16.5 Ah
Working voltage5 V, catalogue value
Static current120 mA, catalogue value
Protection / temperatureIP55 / −30°C to +70°C
Operating altitudeUp to 2,000 m listed
Humidity5–100% listed; condensation conditions require confirmation
Weight7.5 kg including solar panel, listed value
Outer enclosure296 × 212 × 88 mm
Inner enclosure255 × 165 × 68 mm
MountingTwo SUS304 stainless-steel pole straps, listed arrangement
BackhaulCellular variant and operator compatibility to be confirmed
ProtocolsIEC 60870-5-101 / -104 / DNP3, configurable as ordered
Fault-duration identification20–80 ms, configurable claim
Multiple control centresThree simultaneous central connections stated; confirm configuration

Communication architecture sketch

FPI sensors connect over local radio to a DCU and monitoring platform
Conceptual arrangement only. Cellular variant, communication range and SCADA interoperability require project confirmation.

DCU enclosure dimension sketch

Catalogue DCU outer enclosure: 296 by 212 by 88 millimetres
Envelope dimensions quoted by the catalogue. Not to scale; fixing centres, tolerances, cable entries and clearances are not specified.
Confirm before approval. Catalogue statements do not replace equipment-specific data sheets, test reports, utility acceptance or the agreed supply contract. Installation sketches are explanatory and are not certified construction drawings.

Build the right FPI scope for your network

Share your feeder diagram and monitoring requirements. MPE can review equipment selection, supply, installation coordination and commissioning support as an agreed project scope.

Mech Power Engineering — FPI Solutions
Equipment selection, supply, installation coordination, testing and commissioning support for overhead fault indication and monitoring systems. Share your feeder diagram, voltage level, conductor details and SCADA requirements for a project-specific proposal.
Call / WhatsApp: +880 1558-607039 · Email: mechpowerengbd@gmail.com
Office: House-08 (GF), Road-06, Shekhertek Main Road, Dhaka 1207.
Factory: Ahasanpur, Bordeshi, Amin Bazar-1348, Savar, Dhaka, Bangladesh.
Final equipment ratings, test reports, integration scope, availability, software licensing and warranty terms are confirmed in the approved proposal.